Abstract

Verifying the performance of low-carbon binders while at the same time keeping watch over the members they form remains a practical barrier to wider use of sustainable concrete. This work tackles both problems together by applying an electromechanical impedance (EMI) framework, built on embedded lead zirconate titanate (PZT) sensors, to concrete in which refuse-derived fuel (RDF) ash replaces part of the cement. Cube specimens were prepared with ordinary Portland cement (control mix, CM) and with 30% RDF-ash replacement (RDF mix, RM) and were followed continuously over the first eight hours after casting to capture early-age hydration. Separately, reinforced concrete (RC) beams were taken through three progressive damage states and then repaired in three matching stages. Conductance signatures and resonance peaks were recorded throughout and condensed into a single root-mean-square-deviation (RMSD) index. Within eight hours the RMSD reached 14.35% for CM and 12.71% for RM, while the CM resonance peak migrated from 234.6 to 248.3 kHz. As the beams were damaged, conductance fell from 0.0135 S to 0.0089 S and RMSD climbed from 10.53% to 23.01%; staged repair reversed the trend, lifting conductance to 0.0145 S and RMSD to 30.86% as stiffer repair materials altered the sensor signature. The RDF mixture hydrated along a path close to the control and coupled reliably with the embedded sensors, and the EMI response tracked both deterioration and recovery without ambiguity. By placing fresh-state hydration tracking and long-term damage-repair diagnosis within one sensing scheme, the study extends earlier EMI work to waste-derived binders and points toward scalable, life-cycle monitoring that supports circular-economy goals in construction.

Downloads

Download data is not yet available.

References

[1] Naik, T.R., Kumar, R. (2003). Utilization of solid wastes in construction materials. Concrete International, 25(5), 41–48.

[2] Wang, H., Qin, Y., Xin, L., Nan, Q., Xu, X., Zhao, C., Wu, W. (2024). Pilot-scale study of innovative mechanically-enhanced dynamic composting for treating kitchen waste. Bioresource Technology, 394, 130176.

[3] Singh, M., Siddique, R. (2013). Effect of coal bottom ash as partial replacement of sand on properties of concrete. Resources, Conservation and Recycling, 72, 20–32.

[4] Park, G., Sohn, H., Farrar, C.R., Inman, D.J. (2003). Overview of piezoelectric impedance-based health monitoring and path forward. The Shock and Vibration Digest, 35(6), 451–463.

[5] Bhalla, S., Soh, C.K., Gupta, A. (2005). Practical implementation of guided wave-based structural health monitoring for identifying surface and sub-surface damage. Smart Materials and Structures, 14(4), 739–749.

[6] Gencel, O., Ozel, C., Brostow, W., Martinez-Barrera, G. (2010). Mechanical properties of self-compacting concrete reinforced with polypropylene fibers. Materials Science and Engineering: A, 527(3), 997–1004.

[7] Shi, X., Xie, N., Fortune, K., Gong, J. (2012). Durability of steel reinforced concrete in chloride environments: An overview. Construction and Building Materials, 30, 125–138.

[8] Yang, Y., Kwon, O., Spencer, B.F. (2012). Electromechanical impedance-based damage detection in concrete structures using smart PZT patches. Smart Structures and Systems, 9(5), 447–468.

[9] Giurgiutiu, V. (2005). Tuned Lamb wave excitation and detection with piezoelectric wafer active sensors for structural health monitoring. Journal of Intelligent Material Systems and Structures, 16(4), 291–305.

[10] Min, J., Nagarajaiah, S. (2012). Damage detection of a steel frame using mode shape curvature and changes in flexibility. Structural Control and Health Monitoring, 19(5), 601–618.

[11] Liang, C., Sun, F.P., Rogers, C.A. (1994). Coupled electromechanical analysis of adaptive material systems—Determination of the actuator power consumption and system energy transfer. Journal of Intelligent Material Systems and Structures, 5(1), 12–20.

[12] Bhargava, A., Barai, S.V., Paul, D.K. (2006). Nonlinear finite element modeling of corrosion-induced bond degradation in reinforced concrete. Computers & Structures, 84(13–14), 780–788.

[13] Zhang, C., Zhang, Q., Xu, H. (2015). Investigation of the early-age hydration process of blended cement using the electromechanical impedance technique. Construction and Building Materials, 98, 50–56.

[14] Malek, S.M.A., Bae, S. (2016). Structural health monitoring using embedded piezoelectric transducers in reinforced concrete beams. Sensors and Actuators A: Physical, 245, 76–85.

[15] Kim, J.T., Ryu, Y.S. (2010). Damage localization of RC slab using EMI-based SHM technique. KSCE Journal of Civil Engineering, 14(2), 235–243.

[16] Han, B., Zhang, L., Ou, J. (2011). Embedded piezoceramic transducers for monitoring early-age hydration of concrete. Journal of Materials in Civil Engineering, 23(11), 1563–1569.

[17] Lim, Y.M., Park, H.K. (2010). Strengthening of reinforced concrete beams using GFRP: Experimental and finite element analysis. Composite Structures, 92(7), 1650–1659.

[18] Soh, C.K., Bhalla, S. (2005). Calibration of piezo-impedance transducers for strength prediction and damage assessment of concrete. Smart Materials and Structures, 14(4), 671–684.

[19] Ajmal, M., Aiping, S., Awais, M., Ullah, M.S., Saeed, M., Ullah, M.A. (2023). Early-age monitoring of cementitious materials using embedded PZT sensors. Materials Today: Proceedings, 78, 920–926.

[20] Hwang, S.J., Shin, S.W. (2005). Shear behavior of reinforced concrete beams strengthened with FRP plates. Journal of Composites for Construction, 9(6), 493–504.

Downloads

Published

2026-06-12

How to Cite

Kumar, J., Sharma, D., & Bansal, T. (2026). Integrated Monitoring of Early-Age Hydration and Structural Rehabilitation in RDF Ash-Modified Concrete Using Embedded Piezoelectric Sensors. Journal for Research in Applied Sciences and Biotechnology, 5(1), 76–84. https://doi.org/10.55544/jrasb.icaces.8

Similar Articles

1 2 3 4 5 6 7 8 9 10 > >> 

You may also start an advanced similarity search for this article.